{"id":6387,"date":"2026-08-22T09:18:16","date_gmt":"2026-08-22T01:18:16","guid":{"rendered":"https:\/\/bnpanel.com\/?post_type=news&#038;p=6387"},"modified":"2026-08-22T11:04:16","modified_gmt":"2026-08-22T03:04:16","slug":"acoustic-panels-for-offices-what-to-consider","status":"publish","type":"news","link":"https:\/\/bnpanel.com\/nl\/nieuws\/acoustic-panels-for-offices-what-to-consider\/","title":{"rendered":"Acoustic Panels for Offices: What to Consider"},"content":{"rendered":"<p>Kantoor<a href=\"https:\/\/bnpanel.com\/nl\/categorie\/akoestische-panelen-van-hout\/zeshoekige-houten-akoestische-panelen\/\"><strong> akoestische panelen<\/strong><\/a> are chosen on durability, cleanability, and documentation, not appearance alone. Wall panels below desk height take daily impact; ceiling panels must satisfy dead-load limits. The ten checks below cover material, finish, fire scope, replacement stock, and the data buyers should request before an order is confirmed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1755 size-full\" src=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/1-5.webp\" alt=\"Houten akoestische panelen\" width=\"768\" height=\"454\" srcset=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/1-5.webp 768w, https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/1-5-300x177.webp 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/p>\n<h2>1. Map the room by traffic, not by floor area<\/h2>\n<p>A 400 m\u00b2 open-plan floor does not need one panel specification. It needs at least two.<\/p>\n<ul>\n<li>Below approximately 1,200\u20131,500 mm on walls: chair backs, trolleys, bags, cleaning equipment. This is the zone that determines your surface choice.<\/li>\n<li>Above that line, and on ceilings: no contact, so acoustic performance and weight matter more than abrasion.<\/li>\n<li>Circulation corridors and lift lobbies: highest contact frequency per square metre in most offices.<\/li>\n<li>Meeting rooms and phone booths: low contact, but the highest expectation of acoustic result, and usually the first thing a client complains about.<\/li>\n<\/ul>\n<p>Specify the impact zone first, then let the remaining areas follow. Buyers who do it the other way round end up over-specifying an entire floor to protect 15% of it.<\/p>\n<h2>2. Which surface actually survives daily contact?<\/h2>\n<p>The three surface families BEIEN produces behave differently under contact, and the differences are structural rather than cosmetic.<\/p>\n<p>Surface type BEIEN model reference Contact behaviour Practical office note<br \/>\n<a href=\"https:\/\/bnpanel.com\/nl\/categorie\/akoestische-panelen-van-hout\/paneel-voor-huisdieren-met-fineer-ongecategoriseerd\/\">PET polyester fibre<\/a> (exposed felt) BP-01 \u2013 BP-54 Compresses under point impact; fibre surface can pill or catch on rough objects Best above contact height, in meeting rooms, or as ceiling elements<br \/>\n<a href=\"https:\/\/bnpanel.com\/nl\/categorie\/akoestische-panelen-van-hout\/natuurlijk-houtfineer\/\">Natural wood veneer<\/a> on MDF slat NBW series Hard slat face, but veneer is approximately 0.4\u20130.5 mm and shows deep scratches Suits reception and executive areas with lower traffic<br \/>\n<a href=\"https:\/\/bnpanel.com\/nl\/categorie\/akoestische-panelen-van-hout\/technisch-houtfineer\/\">Technical wood veneer<\/a> on MDF slat TBW-01 \u2013 TBW-11 (TBW-12 shown on the website) Same hard slat face, more consistent grain across batches Easier to match on a phased fit-out or a later reorder<br \/>\nPVC surface on wood slat structure PBW-01 \u2013 PBW-06 Moisture-resistant, stain-resistant, easy-clean finish The option to raise where cleaning chemicals are a known issue\u3002<\/p>\n<p>One caution on the PVC line: BEIEN&#8217;s own records show no separate product-specific certification number for the PVC surface panels. If your project requires a fire classification on the installed surface, that has to be resolved with a test on the exact configuration before the surface is written into a specification.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1400\" src=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/2-2.webp\" alt=\"Decoratieve houten fineer PET panelen\" width=\"650\" height=\"520\" srcset=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/2-2.webp 400w, https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/2-2-300x240.webp 300w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><\/p>\n<h2>3. Ask how the facilities team will clean it \u2014 before you choose a finish<\/h2>\n<p>This is the question most often skipped, and the one that decides whether a wall still looks acceptable in year three.<br \/>\nA felt-faced PET panel and a veneered slat panel tolerate completely different cleaning regimes. Offices rarely clean panels the way a specification imagines; they clean them the way the existing contract already cleans everything else on that floor.<\/p>\n<p>Practical approach:<\/p>\n<ol>\n<li>Get the current cleaning schedule and the chemical list from the facilities manager, not from the design team.<\/li>\n<li>Identify any panel zone that will be wet-wiped rather than vacuumed.<\/li>\n<li>For those zones, shift to a hard surface (PVC-faced or veneered slat) rather than exposed polyester fibre.<\/li>\n<li>Request a sample large enough for the cleaning contractor to test their actual product on it, not a 100 mm swatch.<\/li>\n<li>Record the outcome in the handover file, so a future contractor does not undo it.<\/li>\n<\/ol>\n<p>Common misconception: that &#8220;sound-absorbing&#8221; and &#8220;wipeable&#8221; are compatible in the same square metre. They generally are not, because <strong>absorption depends on an open, porous surface and wipeability depends on a closed one.<\/strong> Slat systems solve this by putting the hard surface on the slat face and the porous material in the gaps between slats \u2014 which is why slat construction is the usual answer for offices rather than a compromise finish.<\/p>\n<h2>4.Ceiling installations need weight data, and that data has to exist<\/h2>\n<p>Ceiling-mounted panels introduce a dead-load calculation that wall panels do not. Structural engineers and suspended-ceiling suppliers will ask for kg\/m\u00b2 before they sign anything.<br \/>\n<a href=\"https:\/\/bnpanel.com\/nl\/categorie\/akoestische-panelen-van-hout\/technisch-houtfineer\/\"><strong>Akoestische panelen met houten latten<\/strong><\/a> are supplied at 2400, 2700 or 3000 \u00d7 605 mm with an 18 or 21 mm slat thickness, built from MDF at roughly 760\u2013800 kg\/m\u00b3 with a polyester-fibre backing. A per-panel weight and a finished kg\/m\u00b2 figure for the assembled panel are not currently published. For a wall installation this rarely blocks anything. For a ceiling, it does.<br \/>\nIf you are specifying ceilings, request the following in writing before ordering:<\/p>\n<ol>\n<li>Per-panel weight and kg\/m\u00b2 for the exact model and length<\/li>\n<li>Recommended batten or substructure spacing<\/li>\n<li>Fixing withdrawal capacity for the intended substrate<\/li>\n<li>The fire test report applicable to the ceiling assembly rather than to a wall sample<\/li>\n<\/ol>\n<p>Note also that the CE Type Examination Certificate DE\/7552 (CSI S.p.A., EN 15102:2007+A1:2011, valid 11 June 2024 to 10 June 2029) describes the product as a decorative wall covering, model &#8220;BEIEN WALL PANEL.&#8221; Ceiling use falls outside the wording of that certificate as written, and should be confirmed with the certifying body rather than assumed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2984 size-full\" src=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/12\/using-slat-wall-panels-and-decorative-wood-panels-for-feature-walls.webp\" alt=\"Decoratieve akoestische wandpanelen van houten latten\" width=\"593\" height=\"366\" srcset=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/12\/using-slat-wall-panels-and-decorative-wood-panels-for-feature-walls.webp 593w, https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/12\/using-slat-wall-panels-and-decorative-wood-panels-for-feature-walls-300x185.webp 300w, https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/12\/using-slat-wall-panels-and-decorative-wood-panels-for-feature-walls-18x12.webp 18w\" sizes=\"auto, (max-width: 593px) 100vw, 593px\" \/><\/p>\n<h2>5.Acoustic figures: get the test method or treat the number as marketing<\/h2>\n<p>Compared with the fabric-wrapped mineral fibre systems commonly specified in offices, <strong><a href=\"https:\/\/bnpanel.com\/nl\/categorie\/panelen-voor-huisdieren\/lamellenpanelen-voor-huisdieren\/\">slat and PET panel<\/a> systems are usually chosen for appearance and installation speed as much as for absorption coefficient.<\/strong> That makes it more important, not less, to ask for the underlying data.<br \/>\nBEIEN&#8217;s published catalogue does not currently include NRC or \u03b1w values for the wood slat and wood veneer panel families. The PET Slat Panel product page shows an NRC figure of up to 0.85, but that figure sits alongside other product-page specifications that conflict with the 2026 catalogue and has not been tied to a published test report.<\/p>\n<p>What this means for a buyer: if a project has a written acoustic target \u2014 a reverberation time in a school hall, a speech-privacy requirement in a clinic \u2014 that target should be handled by an acoustic consultant working from measured data on the specific build-up, not from a headline coefficient. Ask any supplier which standard was used (ASTM C423 and ISO 354 give different numbers for the same panel), what the mounting condition was, and whether an air gap was included behind the panel. An absorption figure without a mounting condition is not usable.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1741\" src=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/1-4.webp\" alt=\"PET-panelen\" width=\"586\" height=\"469\" srcset=\"https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/1-4.webp 400w, https:\/\/bnpanel.com\/wp-content\/uploads\/2025\/08\/1-4-300x240.webp 300w\" sizes=\"auto, (max-width: 586px) 100vw, 586px\" \/><\/p>\n<h2>6.Plan the reorder before you place the first order<\/h2>\n<p>Offices expand, get reconfigured, and suffer damage. The panel you buy today needs to be available in eighteen months, in the same colour, in a quantity smaller than the original order.<br \/>\nPoints to settle at quotation stage:<\/p>\n<ul>\n<li><strong>Colour repeatability.<\/strong> BEIEN offers more than 40 standard PET colours plus Pantone and RAL matching. Standard colours are easier to repeat across batches than a custom match; a custom match should include a retained reference sample held at the factory.<\/li>\n<li><strong>Minimum order quantity.<\/strong> BEIEN&#8217;s published information is inconsistent here: the History and Customized Service pages state a standard MOQ of 50 panels, while individual product pages state 100. Confirm the MOQ for your specific product family, finish, and customisation level in writing, and confirm whether it applies to a repeat order.<\/li>\n<li><strong>Spare stock.<\/strong> Buying 3\u20135% extra at the original order is almost always cheaper than a small repeat order later, especially on a custom colour.<\/li>\n<li><strong>Veneer batch variation.<\/strong> Natural veneer varies between batches by nature. Technical wood veneer is the more predictable choice where a later phase must visually match phase one.<\/li>\n<\/ul>\n<h2>7.Check the emissions documentation against the room type<\/h2>\n<p>Schools, healthcare facilities, and enclosed meeting rooms have tighter indoor-air expectations than a warehouse office.<br \/>\nBEIEN operates an<strong> E0-grade material policy for wood acoustic panel raw materials, and displays French VOC A+ documentation and an SGS formaldehyde emission test report on its certificate page.<\/strong> The report numbers, dates, and tested sample scopes on those specific documents have not been consolidated into a single verified register yet. For a project where emissions are a written requirement, request the original documents and check four fields: tested model, test method, result, and validity date.<br \/>\nTwo claims to avoid accepting from any supplier without paperwork: general &#8220;eco-friendly&#8221; statements, and recycled-content percentages. BEIEN&#8217;s own website carries conflicting statements on PET recycled content (100% recycled polyester, 20% recycled content, 100% polyester fibre appear in different places), which is exactly why the company&#8217;s internal rule prohibits using a recycled-content figure until it is verified per product. If recycled content is part of a tender scoring matrix, it needs a document, not a webpage.<\/p>\n<h2>8.Detail the edges, ends, and services before production<\/h2>\n<p>Panel edges are where an office installation looks either finished or improvised. These decisions are cheaper to make in the factory than on site.<\/p>\n<ul>\n<li>Cut-to-length service so slat panels meet a ceiling line without a visible offcut<\/li>\n<li>Cut-outs for sockets, switches, sensors, and access panels<\/li>\n<li>End treatment where a slat run meets a door frame or a glazed partition<\/li>\n<li>Integration of the LED strip system designed to fit the panel grooves \u2014 supplied at 3000K, 4000K or 6000K, 10 W\/m, 24 V, IP67, in 2400 mm and 3000 mm lengths<\/li>\n<li>Accessory positions for shelves and hangers, which BEIEN states are compatible only with its own panels<\/li>\n<\/ul>\n<p><strong>Edge case worth flagging:<\/strong> an open-plan office with a hard ceiling, glazed fa\u00e7ade, and hard floor will not meet a speech-privacy expectation from wall panels alone, no matter how much wall area is covered. Wall panels treat first reflections at seated head height; a reverberant hard ceiling above an open plan generally needs treatment at ceiling level too. If a client has been sold &#8220;acoustic walls&#8221; as a complete solution for that room type, the expectation needs correcting before the order, not after.<\/p>\n<h2>9.Match lead time and packaging to a phased fit-out<\/h2>\n<p>Office fit-outs almost never take delivery of everything at once. Floors hand over sequentially, and site storage is limited.<br \/>\nBEIEN states a standard production lead time of approximately 7\u201315 working days depending on quantity and customisation, with export packaging and coordination for sea, air, and rail transport. Payment is typically T\/T with a 30% deposit and 70% balance before shipment; EXW, FOB, CIF, and DDP terms may be discussed. Pricing is quotation-based and depends on panel type, dimensions, thickness, surface finish, fire-performance requirements, customisation level, packaging, order quantity, and shipping terms \u2014 there is no published price list, and any supplier quoting a firm price before those variables are fixed is quoting something other than your project.<br \/>\nFor phased projects, agree three things at order stage: delivery split by phase, storage responsibility between phases, and how a damaged panel gets replaced without triggering a fresh MOQ.<\/p>\n<h2>Product specifications referenced in this article<\/h2>\n<h3>PET akoestische panelen<\/h3>\n<table border=\"1\">\n<thead>\n<tr>\n<th>Field<\/th>\n<th>Waarde<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Materiaal<\/strong><\/td>\n<td>100% polyester fibre<\/td>\n<\/tr>\n<tr>\n<td><strong>Catalogue sheet size<\/strong><\/td>\n<td>1220 \u00d7 2420 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Thicknesses<\/strong><\/td>\n<td>9, 12, 15, 24 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Colour references<\/strong><\/td>\n<td>BP-01 \u2013 BP-54 (40+ standard colours; Pantone \/ RAL matching available)<\/td>\n<\/tr>\n<tr>\n<td><strong>Customisation<\/strong><\/td>\n<td>Size, thickness, CNC-cut shapes, engraving, private-label packaging, custom logo<\/td>\n<\/tr>\n<tr>\n<td><strong>Fire report on file<\/strong><\/td>\n<td>SHFS2403000289FF, EN 13501-1:2018, B-s2,d0 \u2014 tested sample BN-002 only, 9 mm, 2420 \u00d7 1220 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Dimension conflict to note: certain BEIEN product pages state 1220 \u00d7 2440 mm rather than the catalogue&#8217;s 1220 \u00d7 2420 mm. Confirm the sheet dimension against the current production drawing before it enters a cutting schedule or a tender document.<\/p>\n<h3>Akoestische panelen met houten latten<\/h3>\n<table border=\"1\">\n<thead>\n<tr>\n<th>Field<\/th>\n<th>Waarde<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Profile models<\/strong><\/td>\n<td>BN-01, BN-02, BN-03, BN-04, BN-05<\/td>\n<\/tr>\n<tr>\n<td><strong>Sizes<\/strong><\/td>\n<td>2400 \/ 2700 \/ 3000 \u00d7 605 \u00d7 18 or 21 mm; other sizes available by customisation<\/td>\n<\/tr>\n<tr>\n<td><strong>Construction<\/strong><\/td>\n<td>MDF slats, wood veneer or decorative surface, polyester-fibre acoustic backing<\/td>\n<\/tr>\n<tr>\n<td><strong>MDF density<\/strong><\/td>\n<td>Approximately 760\u2013800 kg\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td><strong>Veneer thickness<\/strong><\/td>\n<td>Approximately 0.4\u20130.5 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Material policy<\/strong><\/td>\n<td>E0-grade MDF<\/td>\n<\/tr>\n<tr>\n<td><strong>Applications stated<\/strong><\/td>\n<td>Muren en plafonds<\/td>\n<\/tr>\n<tr>\n<td><strong>Timber certification<\/strong><\/td>\n<td>FSC Chain of Custody GFA-COC-008037 (GFA Certification GmbH, FSC-STD-40-004 v3.1, 29 Oct 2024 \u2013 28 Oct 2029), applicable within the certified scope only<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>FAQ<\/h2>\n<h3>Q: Are PET panels or wood slat panels better for an open-plan office?<\/h3>\n<p>A: They solve different parts of the problem. PET sheets and PET elements work well above contact height and as ceiling or baffle elements. Wood slat panels give a hard, wipeable slat face at desk and shoulder height with the porous material set back in the slat gaps, which is why they are more commonly specified for walls in circulation areas.<\/p>\n<h3>Q: What fire rating do BEIEN acoustic panels have?<\/h3>\n<p>A: BEIEN holds SGS report SHFS2403000289FF, classifying a 9 mm polyester sound-absorbing board (sample BN-002) as B-s2,d0 under EN 13501-1:2018. That classification applies to that tested configuration. For any other thickness, surface, or panel type, request the report covering that specific configuration rather than assuming the classification carries over.<\/p>\n<h3>Q: Can these panels be installed on office ceilings?<\/h3>\n<p>A: Wood slat acoustic panels are stated as suitable for walls and ceilings. Before a ceiling installation, request per-panel weight and kg\/m\u00b2, substructure spacing, fixing withdrawal capacity, and a fire test report applicable to the ceiling assembly. Also note that CE certificate DE\/7552 describes a decorative wall covering, so ceiling scope should be confirmed with the certifying body.<\/p>\n<h3>Q: What is the minimum order quantity?<\/h3>\n<p>A: BEIEN&#8217;s published information currently shows both 50 panels and 100 panels depending on the page. Confirm the MOQ for your specific product family, finish, and customisation level in writing at quotation stage, and confirm separately whether repeat orders carry the same minimum.<\/p>\n<h3>Q: How much do office acoustic panels cost?<\/h3>\n<p>A: Pricing is quotation-based. It depends on panel type, dimensions, thickness, surface finish, fire-performance requirements, customisation level, packaging, order quantity, and shipping terms. There is no published price list, and a firm figure is only meaningful once those variables are fixed.<\/p>\n<h3>Q: How long does production take?<\/h3>\n<p>A: Approximately 7\u201315 working days depending on order quantity and customisation, with export packaging and sea, air, or rail transport coordination available. For phased fit-outs, agree the delivery split and storage responsibility at order stage.<\/p>","protected":false},"excerpt":{"rendered":"<p>Office acoustic panels are chosen on durability, cleanability, and documentation, not appearance alone. Wall panels below desk height take daily impact; ceiling panels must satisfy dead-load limits. The ten checks below cover material, finish, fire scope, replacement stock, and the data buyers should request before an order is confirmed. 1. Map the room by traffic, [&hellip;]<\/p>","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","class_list":["post-6387","news","type-news","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/bnpanel.com\/nl\/wp-json\/wp\/v2\/news\/6387","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bnpanel.com\/nl\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/bnpanel.com\/nl\/wp-json\/wp\/v2\/types\/news"}],"replies":[{"embeddable":true,"href":"https:\/\/bnpanel.com\/nl\/wp-json\/wp\/v2\/comments?post=6387"}],"wp:attachment":[{"href":"https:\/\/bnpanel.com\/nl\/wp-json\/wp\/v2\/media?parent=6387"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}